- Electric motor testing checks how well a motor runs, how much power it wastes and whether it is safe to use.
- In India, three-phase line operated AC motors are covered by IS 12615 and the BIS ISI mark scheme.
- Main tests include no-load, locked rotor, load and efficiency, temperature rise, insulation and high voltage checks.
- Motors are tested at two levels: the manufacturer’s own lab and a BIS recognised lab.
- Testing is not only for new motors. Running motors in a plant also need regular checks to avoid sudden breakdown.
- Most failures come from poor winding quality, wrong material and weak lab records, so fix these early.
Introduction
Think about the human heart. A doctor does not say “your heart looks fine” by just looking at you. He does an ECG, checks pulse and takes a report. An electric motor is the heart of a pump, fan, compressor or conveyor. It also needs a proper check-up.
Motors use a very big share of the electricity in factories. So a motor that wastes power, overheats or fails early costs a lot, both in money and in production time.
In this blog, we explain electric motor testing in very simple English. You will learn what tests are done, which standard applies in India, how the BIS process works and what mistakes to avoid.
What Is Electric Motor Testing?
Electric motor testing means running a motor under set conditions and measuring its behaviour. The lab checks the electrical values, the heat it produces, its efficiency, its insulation and its mechanical performance. The results are compared with the limits written in the Indian Standard.
The test tells us four simple things:
- Does the motor give the power it claims on the nameplate?
- Does it waste too much energy as heat?
- Is the insulation strong enough to be safe for the user?
- Will it survive normal load and start-up stress?
There are two main reasons for testing. The first is product approval, where a manufacturer tests motors to get and keep a BIS licence. The second is maintenance, where a plant tests running motors to find faults before they cause a breakdown. We cover both in this blog.
For three-phase line operated AC motors, IS 12615 was brought under mandatory BIS certification through a Quality Control Order in 2017. Rules and orders can change, so always check the latest notification before you plan your business.
Which Standards Apply to Electric Motors?
The main standard for common industrial motors is IS 12615. Its title is Line Operated Three Phase AC Motors (IE Code), Efficiency Classes and Performance Specification. It replaced the older motor standard IS 325.
| Standard | What it covers | In simple words |
| IS 12615 | Efficiency classes and performance of three-phase AC motors | The main rulebook for BIS certification |
| IS 15999 (Part 2/Sec 1) | Methods to find motor efficiency | How the efficiency test is done |
| IS/IEC 60034-1 | General rating and performance of rotating machines | Basic rules for rating and heating |
| IS/IEC 60034-5 | Degree of protection (IP code) | How well the body keeps out dust and water |
Simple example: A company makes a three-phase, 5.5 kW, 4 pole motor. The lab measures its efficiency, current, speed and temperature rise on a test bench. It also does insulation and high voltage checks. The results are matched with the limits for that motor rating and efficiency class. If all are within limits, the sample passes.
Note: IS 12615 has been revised over the years, and a newer version also appears on the BIS portal. Always check which version applies to your product and what the transition dates are. Take the latest copy from BIS instead of depending on old files.
Why Is Electric Motor Testing Important?
- Safety: Weak insulation can cause shocks, short circuits or fire.
- Legal need: Motors covered by the Quality Control Order cannot be made or sold without a valid BIS licence.
- Energy saving: Efficient motors waste less power, which reduces the electricity bill over the years.
- Longer life: Tested motors handle heat and load better and run longer.
- Buyer trust: Factories, pump makers and panel builders ask for test reports and the ISI mark.
- Fewer breakdowns: Regular checks on running motors catch small faults early.
- Market checks: BIS can pick samples from the market, so every unit must be made to the same quality.
What Tests Are Conducted on Electric Motors?
Here are the main tests, explained in simple words.
| Test | What the lab checks | In simple words |
| Winding resistance | Resistance of each winding | Shows if the coil is healthy and balanced |
| No-load test | Current and power with no load | Shows basic losses inside the motor |
| Locked rotor test | Current and torque when the shaft is held | Shows starting strength and starting current |
| Load and efficiency test | Output, input, speed and efficiency at set loads | Shows how much energy is used well |
| Temperature rise test | How hot the winding gets | Shows if the motor can run safely for long |
| Breakdown torque test | Maximum torque before the motor stalls | Shows how much overload it can take |
| Insulation resistance | Resistance between winding and body | Shows how safe the insulation is |
| High voltage test | Insulation under high test voltage | Shows if insulation can handle voltage stress |
| Vibration and noise | Shaking and sound level | Shows balance and build quality |
| Marking and nameplate check | Ratings and markings | Shows if the details are correct and readable |
Let Us Look at the Key Tests Closely
1. Efficiency test. This is the heart of IS 12615. The motor is run at different loads and the lab compares power going in with power coming out. The difference is loss. A better IE class means lower loss.
2. Temperature rise test. The motor runs at full load until the heat becomes steady. The lab then measures how much hotter the winding is than the room. Too much heat shortens insulation life quickly.
3. Locked rotor test. When a motor starts, it draws a very high current for a moment. This test checks the current and torque during that moment so that the motor can start the load without damaging the supply.
4. Insulation and high voltage test. These checks protect the user. Even a small weakness in the insulation can become dangerous after some months of use.
Understanding Efficiency Classes (IE Code)
IS 12615 uses the IE code to show how efficient a motor is. A higher number means lower energy loss.
| IE class | Name | Simple meaning |
| IE1 | Standard efficiency | Basic level |
| IE2 | High efficiency | Wastes less power than IE1 |
| IE3 | Premium efficiency | Even lower loss, good for long running hours |
| IE4 | Super premium efficiency | Lowest loss among these classes |
Which class is required for your motor depends on the standard version and the product category. Please check the latest standard and notification, and do not guess.
For a motor that runs many hours a day, a higher efficiency class can save a lot of electricity over its life. That is why buyers now ask for the IE class before they ask for the price.
Testing Motors That Are Already Running
Most blogs skip this part, but it matters a lot for plants. A motor that has been running for years needs health checks too. These are the common ones:
- Insulation resistance test: Done with a megger to check if moisture or ageing has weakened the insulation.
- Winding resistance check: Finds loose joints or shorted turns.
- Vibration analysis: Finds bearing wear, misalignment or imbalance.
- Thermography: A thermal camera shows hot spots in the motor and terminal box.
- Current check: Compares the running current with the nameplate current to spot overload.
- Bearing and noise check: Strange sound is often the first sign of bearing trouble.
A simple rule: test before you repair, and test again after you repair. A rewound motor that is not tested may lose efficiency without anyone noticing.
Two Kinds of Testing: Factory Lab and Recognised Lab
These two are often mixed up, so here is the difference.
| Point | Factory lab testing | BIS recognised lab testing |
| Where | Inside the manufacturer’s own plant | At an approved independent lab |
| Purpose | Routine checks on production | Independent proof for the licence |
| Frequency | As per the scheme of testing | At application time and as BIS asks |
| Who does it | Plant’s own trained staff | Lab staff on lab equipment |
A manufacturer must keep a working in-house lab with calibrated instruments for the required tests. The outside lab confirms the same results independently. Check the BIS list of labs and their scope before sending any sample, so that your tests are accepted.
Step-by-Step Process for BIS Certification of Motors
This is the usual flow for an Indian manufacturer. BIS may update its system, so confirm the latest steps before you start.
- Confirm the product scope. Decide the ratings, poles and IE classes you want to cover.
- Read the standard. Take the latest IS 12615 and the scheme of testing and inspection.
- Check raw materials. Core steel, winding wire, bearings and insulation should be of proper quality and traceable.
- Set up the in-house lab. Arrange test bench, power analyser, temperature measuring tools and insulation testers.
- Calibrate all instruments. Keep valid calibration certificates ready.
- Make trial motors and test them. Find and fix problems before the official test.
- Send samples to a recognised lab. Use proper marking, packing and sample details.
- Apply to BIS and face the factory inspection. A BIS officer visits, checks the process, lab and records, and may pick samples.
- Get the licence and use the ISI mark. Use the mark only as the licence allows.
Which BIS Route Is Needed?
The route depends on who you are.
| Business type | Usual route | Simple note |
| Indian manufacturer | BIS licence under the ISI mark scheme | Factory inspection and lab tests needed |
| Foreign manufacturer | Foreign manufacturers certification route | Needs an Indian authorised representative |
| Importer | Imports only from a BIS licensed source | Customs may ask for licence details |
| Pump, fan or machine maker | Uses ISI marked motors | Must check that bought motors carry the mark |
| Trader | No manufacturing licence | Must sell only genuine marked motors |
A licence may need an update when you add a new rating, frame size or plant. Please do not assume the old licence covers every new model.
Documents Required
Company documents
- Business registration and address proof
- Factory layout and plant details
- Authorised person details
Product documents
- List of motor ratings, poles and IE classes
- Brand name and model details
- Manufacturing process flow and raw material list
Testing records
- Calibration certificates for all instruments
- Routine test records and inspection logs
- Test reports from a recognised lab
How Long Does It Take?
There is no single answer. The time depends on your lab readiness, the lab queue, how fast you reply to BIS queries and when the inspection happens.
Companies with ready records, calibrated instruments and tested trial motors usually move faster. Companies that start with missing papers lose weeks. Please stay away from anyone who promises a fixed date or guaranteed approval.
What About Cost?
The total cost is not one number. It depends on these factors:
- Number of ratings and models to be covered
- Lab testing charges for each sample
- Government application and licence fees
- Cost of setting up or upgrading your test bench
- Instrument calibration charges
- Consultant support, if you take it
- Travel and inspection related expenses
If you want a clear breakup, share your motor range and plant details with an expert.
Common Failures and Easy Fixes
| Common failure | Why it happens | Easy fix |
| Low efficiency | Poor core steel or high winding loss | Use better material and check winding design |
| High temperature rise | Weak cooling or poor insulation class | Improve fan design and slot fill |
| High starting current | Wrong rotor design | Review design and test trial units |
| Insulation failure | Moisture or bad varnish process | Dry and varnish properly, then retest |
| Wrong nameplate data | Careless marking | Check every label against test results |
| Instrument errors | Calibration expired | Keep a calibration calendar |
Common Mistakes in Electric Motor Testing
- Skipping trial testing. Many makers send samples to the lab without testing them first.
- Using uncalibrated instruments. Wrong readings give a false sense of safety.
- Cheap winding wire. Poor wire raises losses and heat.
- Weak records. If it is not written down, the inspector assumes it was not done.
- Copying the nameplate. Ratings must come from real test results, not from a competitor’s label.
- Ignoring the test setup. Loose connections and bad load setup change the result.
- Using an old standard copy. Revised versions can change limits and methods.
- Marking before licence. Using the ISI mark before the licence is granted can lead to action.
Who Needs This?
- Manufacturers: Plants that make three-phase induction motors
- Importers: Anyone bringing covered motors into India for sale
- Private label sellers: Brands that get motors made by another plant and sell under their own name
- Overseas manufacturers: Foreign plants that supply covered motors to India
- Export-only units: Please check with an expert, because rules may differ when goods never enter the Indian market
- Plant and maintenance teams: They need testing methods for running motors, even if they do not need a licence
Why Choose Diligence Certifications for electric motor testing Certification?
BIS work looks simple on paper, but small gaps in files, test setup or lab choice can cost weeks. A guide who has handled such cases can save you from repeated rounds.
At Diligence Certifications, the team explains the process in plain language, helps you understand the standard, and supports you with documents, lab coordination and follow-up with BIS. You can read more about our work on our BIS certification services page.
We do not promise approvals, because the final decision always rests with BIS. What we promise is clear guidance and honest advice at every step.
Conclusion
Electric motor testing is more than a paperwork task. Electric motor testing tells you whether the core of your machine is healthy, efficient and safe. By looking at efficiency, temperature rise, locked‑rotor and insulation tests electric motor testing gives the picture.
If you build motors start by setting up an in‑house lab. Calibrate your instruments. Run electric motor testing, on your own samples before sending them to a recognised lab.
If you use motors at a plant maintain an electric motor testing routine to prevent costly breakdowns.
Begin early follow the electric motor testing standard and keep your records clean.
A little care today saves a lot of trouble later.
BIS Certification
CDSCO
PESO
CPCB
LMPC
WPC Approval
Global Approvals
TEC
ARAI
BEE
ISO Certification
DGCA Certification
NOC For Steel
APEDA Registration
Business Registration
FSSAI Mark Certification
Legal Services
Trademark Registration
Copyright Registration
Patent Registration